
ALT The junctional zone is a thin low contrast region of the inner myometrium, visible on T2weighted MRI images. Investigators have long sought histologic particularities of this region. Here, we summarize evidence that this region's specific appearance is not due to a particular tissue composition, but is a reflection of underlying smooth muscle activity. Smooth muscle tone in the spirally fibered myometrium wrings out blood and interstitial fluids to create a static low-contrast T2 region around the myometrium, while phasic smooth muscle contractions create transient, propagative low-contrast waves. We show that the competition between centripetal inhibitory adrenergic innervation from the serosa and centrifugal excitatory hormonal gradients from the endometrium divides the uterus in a tonic inner-and a quiescent outer-region. Bridging MRI and manometry studies, we discuss the relation between smooth muscle activity and intra-uterine pressure. Dysregulation of nerve and/or hormonal activ

ALT Long-term wearable electrophysiological recording systems are essential for both clinical and real-world environments. While a wide range of wearable devices have been reported for electrocardiogram (ECG) and electromyogram (EMG) recording applications, most electroencephalography (EEG) measurements still require subjects to remain stationary while wearing rigid and uncomfortable equipment. Here, a soft and wearable sponge pillar EEG electrode is presented for long-term and motion-tolerant EEG recording. The electrode is composed of two layers of a carbon black (CB)-polydimethylsiloxane (PDMS) composite, where a firmer solid base assists in bypassing hair, enabling stable access to the scalp, while a porous sponge tip ensures comfort, reliable contact, and low skin-electrode impedance. Fabricated via a sugar templating process without microfabrication steps, the microporous sponge structure offers low modulus and significantly enhances the contact area with the skin when loaded with co

ALT Open-wedge High-Tibial Osteotomy is the most commonly employed technique addressing varus knee osteoarthritis. During this procedure, the osteotome passes through cortical and trabecular bone. A common complication is lateral hinge fractures, which depends upon when the surgeon stops impacting the osteotome. The aim of the present study is to determine whether an instrumented hammer can be employed to detect (i) the bone type (cortical or trabecular) surrounding the osteotome tip and (ii) when bone is fractured by the osteotome. Seventeen lower-limb specimens were obtained from nine fresh human anatomical subjects. The osteotome was impacted using the instrumented hammer until rupture. Each impact signal was recorded and analyzed. An algorithm was developed to detect the transitions between cortical and trabecular bone and vice versa. Detection was based on the relative variation of Ο derived from the force signal as a function of time as the time difference between the secondβndfirst

ALT Background: In many maxillofacial surgeries, the surgeon must perform a pterygomaxillary disjunction in order to separate the jaw from the skull. The disjunction is performed using an osteotome which is impacted with a hammer until its tip crosses through the pterygoid plates. To determine whether the disjunction has occurred and avoid complications, surgeons still rely on their proprioception. Methods: The aim of this study is to validate a vibroacoustic set-up constituted by an instrumented hammer equipped with a force sensor, aiming at detecting if the disjunction has occurred. To do so, fourteen osteotomies were performed in anatomical subject jaws. For each impact, the force signal was recorded and analyzed. A classification algorithm (Support Vector Machine method coupled with a cost matrix) was developed based on indicators extracted from the signal to determine whether the disjunction had occurred. Impacts were classified into two classes, one before and the other after the ost

ALT Various methods such as elastography or mechanical testing have been developed to quantify the mechanical properties of soft tissues, which are related to the tissue local pathophysiological conditions. This study is the first one to investigate the in vivo performances of the Impact-Based Analysis Method (IBAM) to characterize the biomechanical behavior of skin during physiological mechanisms. A murine model (12 Sprague-Dawley rats) was considered and various measurements of skin mechanical properties were conducted on different regions of interest over a 3-week period. The effects of wound healing after full-thickness excisional wound and an intradermal hyaluronic acid (HA) injection were monitored using IBAM, as well as two commercially available devices: Cutometer and MyotonPro. The indicators Ξt (from IBAM), R0 and R5 (from Cutometer) vary significantly as a function of wound healing time, which corresponds to a stiffening of healing tissue compared to healthy tissue. The indicato

ALT Accurate perforator selection is critical for successful deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. While computed tomography angiography (CTA) provides high-resolution anatomical detail, it lacks functional perfusion assessment. Dynamic infrared thermography (DIRT), in contrast, captures superficial rewarming dynamics but lacks objective anatomical validation. This study presents a standardized multimodal measurement system enabling automated fusion of DIRT with CTA-derived perforator coordinates. The framework integrates controlled thermographic acquisition, real-time hotspot detection, metric spatial calibration, and global one-to-one assignment of thermal hotspots to CTA perforators within a predefined periumbilical region of interest. The workflow was evaluated in 12 patients. Of 46 CTA perforators within the region of interest, 84.8% were successfully linked to thermographic hotspots, with a median spatial offset of 14.74 mm. Automated assignmen

ALT Modern position-sensitive PET detectors provide continuous estimates of photon interaction position and event-specific timing, energy, and depth-of-interaction (DOI) information. We introduce Spatial Probability Localization and Transformation (SPLAT), a continuous-domain, event-specific projection model for time-of-flight (TOF) list-mode PET. Each coincidence is represented by a three-dimensional spatial response kernel incorporated into consistent forward and adjoint operators without detector-coordinate binning. While supporting general response distributions, we develop an anisotropic Gaussian implementation whose center is determined by measured interaction positions and TOF difference, and whose full covariance follows from propagating measurement uncertainties through event geometry. The model accounts for DOI, photon non-collinearity, and energy-dependent, correlated, and depth-dependent detector responses. Using GATE Monte Carlo simulations with known annihilation positions, w

ALT Diffusion-based axon radius r mapping preferentially detects larger axons since restricted-diffusion contrast scales with rβ΄, limiting sensitivity to thin axons dominating human white matter (WM). Surface relaxation provides complementary sensitivity through an intra-axonal R2 proportional to 1/r. We combined these mechanisms to broaden the dynamic range of radius estimations. Multi-echo AxCaliberSMT (ME-AxCaliberSMT) models spherical-mean diffusion-relaxation signals using cylinder-restricted diffusion and histologically calibrated surface relaxation. Simulations compared its accuracy and robustness with AxCaliberSMT and a diffusion-filtered R2 model, which infer radius solely from restricted diffusion and intra-axonal R2, respectively. Five healthy adults were scanned on Connectome 2.0 (C2; 500 mT/m), and four also on Cima.X (200 mT/m), using multiple b-values at two diffusion times, each paired with a different echo time. Diffusion and relaxation contrasts were comparable at a proto

ALT Purpose: To develop a scan-specific, interpretable k-space interpolation technique for the reconstruction of accelerated MRI data. Methods: A deep Koopman autoencoder for nonlinear k-space interpolation was developed consisting of an encoder, a linear layer for interpolation and a decoder. The resulting network is implemented using mean square error loss function on k-space neighbourhoods derived from the autocalibration signals (ACS), combining a prediction loss and an autoencoding loss. The approach was compared to GRAPPA and RAKI in 281 retrospectively undersampled brain datasets, using quantitative reconstruction metrics. In a subset of 52 randomly selected images, a clinical reader study compared the proposed approach and RAKI in a forced choice scenario and using a five-point ordinal scoring, assessing sharpness, SNR, aliasing and overall image quality. Additionally, the effect of varying parameters such as the number of autocalibration signals, the contribution of the autoencodi

ALT Purpose: To evaluate the feasibility of whole-cerebrum task-based fMRI on a modern 0.55T system, examining the effects of extended scan duration and within-session consistency on functional mapping outcomes and comparison to acquisition with matched tasks at 3.0T. Methods: Six healthy participants were scanned at 0.55T using a single-shot EPI sequence during bilateral finger-tapping and visual checkerboard tasks. Data were processed using an open-source pipeline. To investigate sensitivity improvements, two consecutive 5-minute runs were concatenated. Within-session consistency was also assessed. A representative 3T dataset provided additional reference context for temporal dynamics and statistical sensitivity. Results: Task-evoked activations were detected at 0.55T using Family-Wise Error (FWE) rate correction (p < 0.05) in both motor and visual cortices. While single 5-minute runs provided baseline detectability, extending the acquisition to 10 minutes increased t-statistic magnitude

ALT Purpose: To evaluate the repeatability and cross-field-strength reproducibility (1.5T vs 3T) of in vivo cerebral myelin fraction (MF) mapping with multi-contrast dual-resolution 3D UTE (multi-UTE), and to compare it with magnetization transfer (MT)-based methods. Methods: MT methods provide an indirect myelin-sensitive measure derived from magnetization exchange between macromolecular and free-water proton pools, whereas multi-UTE targets the ultrashort-T2* signal components. In five healthy volunteers, multi-UTE and MT-based measurements were performed at 1.5T and 3T, and the calculated MF maps were compared with magnetization transfer ratio (MTR) and magnetization transfer saturation (MTsat) maps. Two volunteers underwent repeated multi-UTE measurements within and between days. Field-strength reproducibility and test-retest repeatability were evaluated using linear regression, Bland-Altman analysis, concordance correlation coefficient (CCC), and intraclass correlation coefficient (IC

ALT We describe the detailed design, construction, and testing of a simple, low-cost, open-source, exclusively pneumatic phantom for gated magnetic resonance imaging (MRI) studies of cyclic motion. The overall phantom cost is approximately 200. It is designed to use widely-available materials and an easy-to-program, adaptable micro-controller. Image contrast is generated with air pumped through mineral oil. We demonstrate the utility of the phantom for simulating simple organ motion when developing and investigating image acquisition and reconstruction methods. Phantom motion was independently characterized by video analysis and found to be highly repeatable, with a cycle-to-cycle period variation of 0.6% and a stroke volume variation of 2.3%. The phantom does not generate electromagnetic interference, making it a suitable option for unshielded ultra-low field (ULF) MRI systems. To our knowledge, this work reports the first motion phantom to be imaged on an ULF MRI system

ALT Realizing the potential of optimized acoustic holograms for applications like transcranial ultrasound requires sub-wavelength alignment accuracy (less than 1.5 mm at 1 MHz), which is difficult to achieve with current non-MRI optical neuro-navigation methods. To address the critical challenge of alignment, we leverage the parametric array (PA) signal as an alignment surrogate, a highly penetrative, low-frequency difference wave generated by the nonlinear mixing of two primary high-frequency beams. Simulations show that a misaligned skull-compensating lens increases the primary acoustic energy within the skull bone (volumetric energy trapping), which strengthens the nonlinear source of the PA signal. We also tested whether shear-mode conversion in bone contributes: 2D elastic simulations showed only a small (3-5%) increase in shear-type motion with misalignment, and the transmitted ex vivo bursts did not lengthen as a shear path would require. Pseudo-sound and microbubble artifacts were

ALT Quantitative imaging (QI) provides a non-invasive approach for dosimetry and quantitative response assessment in radiopharmaceutical therapies (RPTs). QI methods are being developed for instrumentation, acquisition, reconstruction, and image analysis. However, a key barrier to routine adoption of these methods is that evidence demonstrating reliable performance of QI methods on clinically relevant quantification tasks in RPTs remains limited. Our goal is to outline the Evaluation of Quantitative Imaging Performance in Radiopharmaceutical Therapy (EQUIP-RPT) framework, a structured approach for objective, task-based evaluation of QI methods for RPTs. We outline the EQUIP-RPT framework based on image-science and task-based image-quality evaluation methodology, practical considerations, and recent literature. The framework is organized around four linked design steps: (i) specification of the quantification task, (ii) design of the study population and imaging protocol, (iii) task-specifi

ALT Background: In NM-imaging, theoretical curves for the recovery coefficient (RC) of the signal maximum and mean are known for spheres and cubes, if a 3D Gaussian PSF is assumed. The RC of the maximum is also known for cylinders. For these and other shapes empirical equations with one or two fit-parameters have been utilized. Methods: An equation for the RC for large objects of arbitrary shape is derived and generalized into an empirical equation for smaller objects, which is verified by numerical simulations. The proposed equation is compared to published results on SPECT kidney phantom measurements and to PET measurements on the NEMA IEC PET body phantom with six spheres. Results: The signal loss (1-RC) for large spheres is inversely proportional to the radius, where the slope is proportional to the FWHM of the spatial resolution. For non-spherical shapes the generalized instead of the volume equivalent radius should be utilized. For smaller objects, an equation with one added empirica

ALT Cardiac digital twins (CDTs) provide a computational platform for personalized cardiac modeling, but their predictive behavior depends strongly on the selected ionic model and the representation of transmural electrophysiological heterogeneity. In this study, we developed a multiscale CDT validation framework that integrates physiologically optimized hierarchical configurations. Using single-cell (0D) models and three-dimensional (3D) patient-specific ventricular models, we implemented the ten Tusscher-Panfilov model (TT2) and Tomek ionic model and compared their electrophysiological responses across a range of pacing frequencies, with basic cycle lengths (BCLs) from 600 to 4000 ms. The results show that tissue-level electrical coupling substantially reshapes the intrinsic dynamical properties observed at the single-cell level. By benchmarking model outputs against clinical data, this study quantifies fidelity differences between the two ionic models across multiple scales and provides

ALT Radiation therapy treatment planning is a labour-intensive process prone to inter-expert variability. Deep learning (DL) dose prediction can accelerate this process, but most DL models do not quantify their reliability. In this study, we construct prediction intervals for DL-based radiotherapy dose prediction using split conformal prediction (CP), a model-agnostic and distribution-free method for uncertainty quantification that provides finite-sample coverage guarantees. We propose patient-level nonconformity scores obtained by aggregating voxelwise scores. Specifically, we formulate a maximum aggregation construction, which guarantees simultaneous coverage of the true dose in all voxels of a future patient with at least a user-defined probability, and a quantile-based construction, which guarantees, with the same probability lower bound, that a future patient attains a prescribed minimum level of voxel coverage. We also investigate groupwise calibration for region-specific guarantees

ALT Estimating the myelin water fraction (MWF) from multicomponent T2 relaxometry requires solving an ill-conditioned inverse problem, making estimates sensitive to noise. Regularization can improve stability but may introduce bias. Conventional NNLS-based methods also provide point estimates without directly quantifying voxelwise variability. To address these limitations, we propose the non-negative least squares Bootstrap Barycenter (NNLS-BB), combining residual resampling with repeated NNLS reconstruction. We average spectra and derived parameters across bootstrap replicates and use their standard deviations to characterize sensitivity to signal perturbations. The method requires neither an explicit spectral regularization penalty nor a training dataset. NNLS-BB was evaluated on 40,000 simulated voxels with signal-to-noise ratios of 50-1000, against conventional NNLS, two regularized NNLS methods, and a model-informed machine-learning (MIML) method. Scan-rescan repeatability was assesse

ALT Quantum amplitude estimation (QAE) promises a quadratic reduction in the sampling cost of Monte Carlo (MC) particle transport, but two obstacles have kept it from radiotherapy physics: the lack of an efficient unitary encoding of charged-particle transport, and the mismatch between QAE's single-scalar output and the per-voxel structure of dose calculation. We address both. We construct a discrete-time quantum-walk transport oracle for protons in which an energy register is driven by an energy-dependent coin encoding a continuous-slowing-down surrogate of the stopping power, so that stochastic energy loss and range straggling follow from the circuit dynamics. The oracle is unitary, with one fresh coin qubit per step, and its gate count grows linearly in the number of energy levels. On it we formulate a scalar range statistic, the probability that a proton penetrates beyond a distal depth threshold, as a directly marked amplitude, and estimate it by maximum-likelihood amplitude estimatio

ALT Purpose: Inter-scanner variability in cerebral blood flow (CBF) quantification limits reproducibility in multi-center arterial spin labeling (ASL) studies. We developed and validated a vendor-agnostic pseudo-continuous ASL (PCASL) sequence using the open-source Pulseq framework, and assessed its extensibility to advanced perfusion imaging. Methods: A vendor-independent PCASL sequence was implemented in Pulseq and deployed on 3T scanners from Siemens, GE, and United Imaging. Seven healthy volunteers underwent single-post-labeling-delay (PLD) PCASL on all platforms, including test-retest scans. An in-house adapted Siemens vendor-based PCASL sequence served as reference. Reproducibility was assessed using within-subject coefficient of variation (CVwithin), root mean square error (RMSE), regional CBF correlation, and voxel-wise variation ratio maps. Multi-PLD PCASL and planning-free VE-PCASL were implemented as proof-of-concept extensions. Results: Mean gray matter (GM) CBF was similar acr
