Cardiac Electrophysiologist and Director, Centre for Heart Rhythm Disorders | Adelaide University | Royal Adelaide Hospital. Associate Editor #EHJ
Adelaide, Australia
Joined April 2012
- Tweets24.2K
- Following690
- Followers9.5K
- Likes24.3K
Pinned Tweet
CAAN-AF Trial #CHRD @adelaide87018
Our previous meta-analysis of observational studies suggested CRT patients with AF had a significant 58% reduction in all-cause mortality with AV node ablation - jacc.org/doi/10.1016/j.jacc.…
We designed the CAAN AF Trial supported by the @nhmrc and critical industry partners - in order of support @bostonsci @AbbottNews @Medtronic @MicroPort - Methodology paper - heartrhythmopen.com/article/…
CAAN AF Trial: doi.org/10.1093/eurheartj/eh…
RCT showing no benefit in the routine use of AV node ablation
Prash Sanders retweeted
Cardiac Electrophysiology at a Crossroads: Building on Dr. Josephson's 20 years of observations. Is EP science, procedure or both? What is the future of EP science?
authors.elsevier.com/a/1nzSl…
#EPeeps #CardioX @ACCinTouch @HRSonline
Prash Sanders retweeted
‼️ Now online in the #EHJ @ESC_Journals: The Vasc-PFA study
📖 academic.oup.com/eurheartj/a…
@ehj_ed
Our study provides important insights into the acute coronary vascular effects of monopolar biphasic #PulsedFieldAblation
🔬 Key findings:
👉 Acute, localized endothelial dysfunction occurs following coronary exposure to PFA, while vascular smooth muscle function remains preserved.
👉 The effects are site-dependent: endothelial dysfunction was least pronounced after cavotricuspid isthmus (CTI) ablation and most evident following great cardiac vein (GCV) and epicardial PFA.
👉 Selective endothelial injury with preserved smooth muscle cell function may explain the observed vasomotor dysfunction and why nitroglycerin can rapidly reverse clinically apparent coronary spasm despite persistent endothelial impairment.
📌 Why does this matter?
Anatomical factors may influence electric field delivery and the degree of coronary exposure. The findings also raise important questions about the potential relationship between acute endothelial injury and delayed coronary complications, including myocardial ischaemia, ventricular arrhythmias, and longer-term vascular remodelling.
#PulsedFieldAblation #Electrophysiology #CardiacElectrophysiology #Cardiology #CoronaryArteries #Arrhythmia #CardiacResearch
@drjohnm @DrJasonAndrade @TinaBaykaner @DrRoderickTung @ftrae @peterkistler3 @ivroca @shivkumarmd @LuigiDiBiaseMD @nmarrouche @S_NarayanMD @Dr_Santangeli @atulverma_md @SCYap77 @VivekReddyMD @MoritzNies @jskoruth
@arnelasaljic @DalgasSarah
@PrashSanders @harry_crijns @Elliott_AD @kvernooy @Ed_Gerst @True_EP @Drdevignair @Mel_Gunawardene @jongichun @RolandTilz @Phiso_de
lnkd.in/p/eNvPWUK9
New study investigates coronary endothelial dysfunction in Pulsed Field Ablation (PFA).
doi.org/10.1093/eurheartj/eh…
#PFA #arrhythmia #AF #cardiotwitter, @ESC_Journals @escardio
Prash Sanders retweeted
New study investigates coronary endothelial dysfunction in Pulsed Field Ablation (PFA).
doi.org/10.1093/eurheartj/eh…
#PFA #arrhythmia #AF #cardiotwitter, @ESC_Journals @escardio
Prash Sanders retweeted
Durability of pulmonary vein isolation: Does the pulsed field ablation system matter? #OpenAccess
@PrashSanders @UniofAdelaide
heartrhythmjournal.com/artic…
Prash Sanders retweeted
4/4
🎯Discussion:
➡️The proposed mechanism is plausible: balloon-in-basket geometry may provide more uniform circumferential tissue contact and electric-field delivery, while pentaspline PFA depends more on apposition, rotation and lesion overlap.
➡️Previous data - Pentaspline PFA delivers targeted tissue transfer efficiency of only 2.7%. (loss to blood flow) vs. 12% with balloon-in-basket PFA
pmc.ncbi.nlm.nih.gov/article…
🤔Caution:
➡️The durability comparison rests on only 17 redo pts.
🧑🎓Povocative data, and the biological hypothesis deserves prospective testing. Platform effect, technique effect—or both?
So, if you would like to redo the poll -
Prash Sanders retweeted
3/4
🔯Results
➡️PV reconnection
🔴 Farapulse: 28.1% (9/32) vs. Volt: 2.9% (1/35) (p=.003)
➡️All PVs durably isolated/patient
🔴 Farapulse: 37.5% vs. Volt: 88.9% (p=.049)
➡️Farapulse failures clustered in the inferior veins (7/9)
➡️Clinical Recurrence, however, was equivalent:
🔴 Farapulse 17.6% vs. 🔵 Volt 20.6% (p=0.1)
The disconnect between electrophysiologic durability and clinical recurrence could be explained by methodology (symptomatic recurrence in FP vs. protocol-driven monitoring in Volt).
Prash Sanders retweeted
🔯Study Details:
➡️Retrospective, 2-center study of 132 consecutive pts. undergoing de novo PFA for symptomatic AF: Farapulse (n=86) and Volt (n=46).
➡️Farapulse - 53.5% Paroxysmal
➡️Volt - 60.9% Paroxysmal
➡️100% acute PVI.
➡️ Recurrence at median 14.3 months - Farapulse (10.5%), Volt (19.6%)
➡️ Redo ablation - 8 Farapulse and 9 Volt.
✴️These were not equivalent cohorts. Volt was trial-protocol-derived, whereas Farapulse represented routine real-world practice, with ⬆️ HF burden & ⬇️ LVEF.
➡️Propensity matching (34 pairs) balanced baseline characteristics for comparison of clinical recurrence—but could not be matched for the durability analysis.
heartrhythmjournal.com/artic…
Prash Sanders retweeted
🧵1/4
"Durability of pulmonary vein isolation: Does the pulsed field ablation system matter?" @PrashSanders et al in @hrs_journal Oct 2026 @HRSonline
✴️An interesting challenge to our assumptions.
➡️ Question - Are PFA systems comparable for
long-term PVI durability after equivalent acute PVI?.
➡️Let's start with a poll for #EPEEPS
✴️ Which PFA platform do you currently favor for AF ablation?
Prash Sanders retweeted
Back from the 21st Annual International @VTSymposium in New York. Thank you to the course directors Frank Marchlinski, Dave Callans, @Davilandre , Vivek Reddy and Srini Dukkipati for the invitation. Grateful to have been there as faculty and to share our experience with subcutaneous, extravascular and parasternal ICDs, including our workflows for safe, efficient and innovative implants, such as video-assisted access to the retrosternal space.
It was also an honor to present IMPACT-CTI as one of three finalists in the Late-Breaking Clinical Trial session, asking whether energy source impacts the chronic effect on the coronary artery when ablating at the cavotricuspid isthmus. Simultaneously published in JACC:Clinical Electrophysiology.
Thank you to my co-authors and to the @ARGJonesboro team in Jonesboro.
And the best part, as always: seeing so many friends. As @NeuzilPetr put it, the elegant VT Club. 🫀
#VTSymposium #Electrophysiology #PulsedFieldAblation #ICD #EPeeps #CardioTwitter
@StBernards @natale_md @LuigiDiBiaseMD @atulverma_md @shivkumarmd @Dr_Santangeli @DrFerminGarcia @JosefKautzner @ivroca
@PaoloDellaBell1 @EladAnter
Prash Sanders retweeted
#mHEALTH for integrated care: does it work and what can be done to make it effective? 📱📚
Join us in this discussion on the #AFFIRMO trial, live from #HRX
@HRSonline @experienceHRX
NEW EPISODE OF THE LEAD!
[Ep. 172] A Discussion of Integrated Care Management and Comprehensive Geriatric Assessment Using an mHealth-based Approach in Older Multimorbid Patients with Atrial Fibrillation: The AFFIRMO Cluster-Randomized Trial
🎙️ Host: Melissa E. Middeldorp, MPH, PhD, FHRS (@melissaemm1)
🎤 Guests: David J. Slotwiner, MD, FHRS (@dslotwin) and Alessandra Pina, MBBS, MD (@Alessandrapina_)
Listen on your preferred podcast platform
➡️ bit.ly/48bpxNn
#EPeeps #medpod #podcast #CardioTwitter #EPTwitter #PodcastAndChill
Prash Sanders retweeted
The next episode of REVOLT is now live!
This time, Prof. @PrashSanders explores PFA lesion morphology and how our #VoltPFA System's design and features impact lesion depth and durability.
Watch now: bit.ly/4yXjfhE
Safety Info: bit.ly/3TyAoiy
#AbbottProud
Prash Sanders retweeted
Congratulations to Dr. Hidehiro Iwakawa, Dr. Prashanthan Sanders, and the full author team on their new publication in Heart Rhythm: "Leadless pacemaker, right ventricular pacing burden, and heart failure."
It's a privilege to see PaceMate data support research that shapes how clinicians care for device patients.
Read the full open-access study: lnkd.in/esy7mjb9
Prash Sanders retweeted
Non-Invasive Median Nerve Stimulation with a Wearable Stimulator to Reduce Atrial Arrhythmia Recurrence after Atrial Fibrillation Ablation: The NEUROPULSE Pilot #OpenAccess
heartrhythmjournal.com/artic…
Prash Sanders retweeted
Heart Rhythm TV host Deepthy Varghese, DNP, ACNP, FNP, sat down with ARG Principal Investigator Dr. Devi G. Nair, MD, FHRS, to discuss the first-in-human feasibility of next-generation 4D intracardiac echocardiography for left atrial appendage closure +
Prash Sanders retweeted
From pitch to podium: @atrility claimed 1st place at the HRX 2026 Pitch Competition! 🏆 Judges and audience members alike were captivated by their innovative idea. See the full interview here #EPeeps ➡️ bit.ly/3T29AqT
To learn more about Atrility, visit atrility.com/
@MehakDhande @jczerpa @Nashwa_Salem_ @naijaQRS @alexandra_regia @kcole_12 @melchami99 @NaimaMaqsood9 @HeartRhythmNP @AZ_EP_DOC @OliverMonfredi @np_varghese @atulverma_md
Prash Sanders retweeted
2026 HRS/EHRA scientific statement on pulsed field ablation for cardiac arrhythmias
heartrhythmjournal.com/artic…
We are thrilled to announce that Dr. Charles Love is joining the Murj team as our new Chief Medical Advisor of Electrophysiology! Dr. Love is an internationally recognized pioneer in cardiac rhythm devices, and we are incredibly excited to partner with him to advance our clinical software innovation and strategy.
Dr. Charles J. Love is an internationally recognized electrophysiologist, arrhythmia device specialist, and pioneer in lead management. Among other distinguished roles, he previously served as Professor of Medicine and Director of Cardiac Rhythm Device Services at Johns Hopkins Hospital, as well as President and Chair of the International Board of Heart Rhythm Examiners (IBHRE). Dr. Love has implanted over 9,000 devices and has removed in excess of 3,000 pacing and defibrillator leads. Having consulted with numerous cardiac rhythm, extraction, and biomedical device companies regarding new device design, he brings unrivaled experience and clinical perspective to his new role as Chief Medical Advisor of Electrophysiology at Murj.
Prash Sanders retweeted
NEW on Heart Rhythm TV: #HRStv host @melchami99, sits down with co-author and new HRStv member @atulverma_md, to discuss "2026 HRS/EHRA Scientific Statement on Pulsed Field Ablation for Cardiac Arrhythmias," published in the September issue of @hrs_journal.
See the full interview here #EPeeps ➡️ bit.ly/4dPywJ1
@MehakDhande @jczerpa @Nashwa_Salem_ @naijaQRS @alexandra_regia @NaimaMaqsood9 @HeartRhythmNP @AZ_EP_DOC @OliverMonfredi @np_varghese