Seek Thermal (@SEEK_Spain) header
Seek Thermal (@SEEK_Spain) profile picture

Cámara térmica SEEK Reveal Fire Pro para Bomberos. #EPI #PRL #RIT #FirePro #IIFF #USAR #INSARAG #K9 #IncendiosEstructurales #TIC Industrial Global Supply

España
Joined October 2019
Photo by Seek Thermal (@SEEK_Spain)Photo by Seek Thermal (@SEEK_Spain)Photo by Seek Thermal (@SEEK_Spain)Photo by Seek Thermal (@SEEK_Spain)Photo by Seek Thermal (@SEEK_Spain)Photo by Seek Thermal (@SEEK_Spain)Photo by Seek Thermal (@SEEK_Spain)Photo by Seek Thermal (@SEEK_Spain)Photo by Seek Thermal (@SEEK_Spain)Photo by Seek Thermal (@SEEK_Spain)
Seek Thermal retweeted
Interested in the Seek Thermal Fire PRO 300? Check out this highlight of our Search demonstration at the GTCC Insight Fire Training TIC Academy where the students were using their devices to assist them with quickly locating areas of interest, orientation, object and hazard identification. Learn more about this device here: youtu.be/Ii9ojIXzqAI?si=1Bq4…
4
5
387
Seek Thermal retweeted
La instalación de detectores de humo en vivienda es obligatoria en media Europa. En España, lo será sólo para las viviendas de nueva construcción. ¿Qué pasa con el resto? Ponte un detector; que no sea por obligación, sino porque te puede salvar la vida... @EuroFSA @fmapfre #APTB
8
1
8
483
Otro Servicio de Emergencias más que confía en #SEEK Enhorabuena, Bomberos de Almería! @seekthermal #bomberos #almeria @IGS_Spain
🤖 Made with AI
1
1
168
El Consorcio de Bomberos de la Región de Murcia da un paso estratégico al frente en innovación táctica y seguridad operativa con la adquisición de 85 nuevas cámaras térmicas #Seek #F300 #VRS 🔴 Protegemos lo que más importa. #Murcia POR TU SEGURIDAD!! @seekthermal @IGS_Spain
🤖 Made with AI
2
3
290
Seek Thermal retweeted
Replying to @Escuela_SAMU
@Escuela_SAMU Esta mañana hemos realizado prácticas de rescate con vehículos pesados en las magníficas instalaciones que tiene #SAMU en Sevilla. #paratech #heavyrescue #bomberos
2
3
209
La importancia de la GANANCIA MIXTA en las cámaras térmicas. Hasta que no pruebes nuestra SEEK no lo vas a entender. xitter.gq/seekthermal/status/201… @IGS_Spain
4
123
Hoy hemos sorteado una cámara térmica SEEK F300 y el precio se ha ido para bombers del Consorcio de Valencia. Enhorabuena Jose Vicente! @seekthermal @IGS_Spain Mañana tenéis otra oportunidad de participar. Os esperamos en nuestro stand! Pabellón 8 / 8B07 #sicur
1
102
Como todos los años, os esperamos en #SICUR en el stand de @IGS_Spain @seekthermal
37
Este año no te querrás perder #SICUR Tenemos preparado algo especial para los que vayáis a nuestro stand de @IGS_Spain #seekthermal #bomberos @seekthermal
1
1
3
374
Seek Thermal retweeted
Check out our next FREE webinar sponsored by Seek Thermal How Thermal Imaging Cameras Can Benifit RIT Training! attendee.gotowebinar.com/reg…
2
2
202
Seek Thermal retweeted
Ayer fue el tercer y último día de formación #Paratech en #bomberos de #Murcia. Nos vemos de nuevo el mes próximo! #heavyRescue #spain @Paratech_Inc Movimiento de cargas con #bipode
3
8
582
Seek Thermal retweeted
ÚLTIMOS DÍAS: este jueves, 15 de enero, es el último para inscribirse en los másteres y cursos de Especialistas en #Incendios y #Emergencias, que organiza la @UNED con la colaboración de @cogitimadrid y # APTB. Formación de máximo nivel. No te quedes fuera...
1
6
12
1,062
Como puede ser que algo tan pequeño y asequible te pueda salvar la vida? #bomberos @seekthermal @IGS_Spain #seek #F300
1
3
117
Buenos días y buena semana para todos. Hay alguno de vosotros que aún no haya probado nuestra SEEK F300? A qué esperas? @IGS_Spain Recuerda; la de color rojo; el color de los bomberos
1
1
75
Seek Thermal retweeted
Feliz Navidad y próspero 2026 !
2
3
114
Thank you @firedexppe for your continued support! Insight Training proudly wears AeroFlex & TECGEN71 PPE #thepatch #firedex #firedexppe
2
7
441
TIC Scanning Techniques: Do you know that the refresh rate of your TIC could cause you to miss a victim? There are many high quality thermal imaging fire service devices currently available for firefighters today. However, an often neglected area of discussion is the “refresh rate” or frame rate of the detector. When a TIC delays information to the firefighter, critical information is missed! Imagine how big of an area can be missed by a firefighter conducting a search, with a 3 second delay on the screen. In a small room, that area may be only a few feet. In a large, open area, the amount of searchable area missed could be costly. Fire Service TICs that have less than 25 hertz refresh rate or those that claim faster refresh rates but suffer from delays when switching between gains can cause firefighter to: * Miss the fire room * Miss the victim * Miss their crew or their egress point when they are lost or disoriented. Per NIST Technical Note 1499 (which was the basis for NFPA 1801): “The display refresh rate is important in applications in which the camera operator may be moving and/or constantly scanning the scene.” It’s important to clarify that specifications on paper don’t always equate to higher performance inside the fire environment. Fire service TICs vary in refresh rate from: * 9 hertz * 16 hertz * 25 hertz * 30 hertz * 60 hertz The frame rate or refresh rate is not the sole determining factor in the speed of image processing. Many devices that have higher refresh rates actually have a delay when switching from high to low sensitivity. For example, a firefighter who scans a room and views from a cold area to a hot area can experience any of the following changes with a TIC: * Image or Screen Freeze * A brief flash of white before the TIC switches to low sensitivity. A firefighter needs to know this BEFORE they go to their next fire! Check out a highlight of our hands on demonstration in Poland that we conducted before completing the live fire training portion. Stay Intelligently Aggressive! Insight Fire Training Thermography Certified Fire Service Professionals
3
12
707
Do you train your firefighters on how to properly scan with a TIC? In the last two years, we have reviewed 9 MAY-DAYs and near miss incidents that all involved improper scanning techniques which were due to: * Failure to wipe lens. * Standing up. * Scanning high instead of scanning low to high. * Misinterpretation by reading the spot temperature or failure to identify convection currents. * Failure to identify hazards. Follow us for more training tips on how to educate firefighters! Insight Fire Training
1
5
290
🔥Entras y ves esto, ¿qué hacemos? Para los del gremio 👉🏼¿ataque directo, indirecto, 3D… ? Comenta! 👀
8
3
1
52
3,378
Replying to @DutyFire
En un incendio desarrollado lo mejor es gran caudal a la base de las llamas para hacerte con el . Pero generaría mucho vapor. Yo haría 2 0 3 impulsiones al techo con cono medio y gran caudal y luego pasaría al ataque directo
1
1
10
411