Dr. Diego López retweeted
More caudally, the axial postop CT image shows the caudal PW and transverse details
Dr. Diego López retweeted
The postop axial CT at the dome level shows the detailed results of the reduction and fixation and bone grafting
Dr. Diego López retweeted
The IO view shows that the caudal screws (and in this case the cranial ones too) are not in the joint
Dr. Diego López retweeted
The plates should be well contoured to have uniform contact with the cortical bone surfaces - the OO view shows the cranial screws and the long AC screw to be not in the joint
Dr. Diego López retweeted
Then the contoured malleable plates are positioned to support the PW fragments and further secure the Transverse as well - you can see that several plate screws are interfragmentary screws through the cranial and caudal PW fragments
Dr. Diego López retweeted
Using biplanar fluoro, the AC part of the TR fracture reduction is secured with a percutaneously inserted 4.5mm cortical lag screw
Dr. Diego López retweeted
Once the fracture surfaces have been cleaned, the transverse fracture is reduced and clamped, the impaction articular pieces reduced and grafted, and then the PW fragments are reduced and wired
Dr. Diego López retweeted
The intraop obturator oblique shows the minimal transverse location and displacement, plus the displaced PW cranial and caudal fragments
Dr. Diego López retweeted
The intraop iliac oblique image shows the femur beneath the intact dome and the lucency due to the displaced PW fragments and impaction from the prior dislocation
Dr. Diego López retweeted
An intraop AP image prior to beginning the surgery shows the benefit of Rx muscle paralysis and prone positioning to reduce/maintain the femur beneath the intact dome - the displaced transverse and PW fragments are also seen - traction was not necessary during the operation
Dr. Diego López retweeted
We used prone positioning on a regular table with no traction and a focal prep/drape to access the injury at surgery via a KL exposure
Dr. Diego López retweeted
This axial image shows the caudal portion of the transverse fracture, the displaced proximal femur, and the displaced caudal PW fragment
Dr. Diego López retweeted
This image demonstrates the component parts of the injury - the intact pelvis, the displaced Tr posterior limb at the GSN, the cranial PW fragment, and the caudal PW fragment
Dr. Diego López retweeted
This axial image shows how much of the dome is with the displaced cranial PW fragment
Dr. Diego López retweeted
The axial CT shows the slight displacement of the transverse portion but more importantly the minimal amount of intact dome for the head to be maintained beneath - the majority of the dome is a part of the displaced cranial PW fracture fragment
Dr. Diego López retweeted
Transverse with associated PW acetabular fractures have a spectrum of injury details - this 56yoM has a frx dislocation that is quite difficult to maintain the closed reduction - can you see why? The film label says “post reduction” but it’s not reduced! Why?
Dr. Diego López retweeted
Lo feliz que hace a los pacientes poder reimplantar algo tan pequeño...
Hablaremos de estos casos tan extremos en el próximo congreso mundial de microcirugía.
@AEMMicrocirugia @SecmaSociedad @SECPREorg
Dr. Diego López retweeted
Replying to @CherneySteve @ChipRoutt
And for rotation, there's some recent evidence we aren't good at getting this this but a good ballpark (aside from checking contra-limb), tibial tubercle in line with the crest in line with the 2nd MT
Dr. Diego López retweeted
Replying to @CherneySteve @ChipRoutt
Alignment: talus should be centered under the tib shaft on both views. This should get you most of your alignment. Talus should be about perpendicular to the shaft of the tibia on the AP, and there should be 10' of tilt on the lateral (but the contra limb is good for templating)





















