Prosto Echo retweeted
A patient admitted after trauma. No prior cardiac history. What is unusual about this finding?
Prosto Echo retweeted
Rare Case 🚨
A 36-year-👦 with prior aortic valve replacement & Dacron graft for AR/root dilation presents with sternal notch swelling & retrosternal pain 🫀
📄 doi.org/10.1093/ehjci/jeaf08… #CardioTwitter #Endocarditis #CaseReport #CVImaging #echofirst #yesCCT @ESC_Journals
F 61, severe Cardiac Cachexia, possibly rarely seen in the west,severe rheumatic MR, AR, and severe TR, RVP 60 mmHg, told erroneously many years ago that she was “inoperable” she was operable then.
Now she is in poor general condition.
It is challenging to make her fit 4 surgery
Prosto Echo retweeted
partial aortic valve leaflet fusion (forme fruste BAV, or mini-raphe), previously considered TAV by #Echofirst 👀 by #yesCCT results in alteration of aortic flow patterns, consisting of increased flow eccentricity and increased vortexes https://xitter.gq/t.co/N2SAmVIdFL – at Pittsburgh, PA
Prosto Echo retweeted
Incidental #echofirst finding in a Pt. with acute aortic dissection: an anomalous retroaortic LCx originating from the right aortic sinus, recently highlighted by @CASivaram1.
@alex1708ander @NMerke @danimilovanovi1 @iceman_ex @echo_stepbystep @iamritu @DirkEggert
Prosto Echo retweeted
3D adds perspective. 2D delivers resolution. You need both. Simultaneously. #echofirst
A good 2D image beats a poor 3D one. Every time.
Eccentric PR. Adult patient without CHD. H/o native PV endocarditis.
Deep TG PV view, intraop TEE.
3D image ≠ 3D probe. Know the difference
Prosto Echo retweeted
TEE mid esophageal at 90. “Crack” the pathology😀. #echofirst @WvuCvFellows @argulian @CASivaram1 @harshi_md @iamritu
Prosto Echo retweeted
#JADEL
Hey #EchoFirst gurus!
What do you think of when you see an echo that looks like this?
HINT: Look at the anatomic location of the desc AO.
A. Marfan
B. Barlow
C. Pectus
D. AV canal
E. Tetralogy
Follow thread for answer(s) and additional "imaging".
@ASE360
Prosto Echo retweeted
Left atrial appendage with a very long wing, 3D TEE, low tissue transparency. Anatomic variability never stops to amaze!
Prosto Echo retweeted
#echofirst
✅ Time to close. 🙏 for all responses.
✅ Diagnosis: Severe AS with high gradients (peak velocity 4.6 m, PG 85, MG 51, AVA 0.2) & moderate AR; low EF (~20) but preserved contractile reserve (post PVC ⬆️ gradient)
✅ This is unequivocal severe AS. Unlike low flow low gradient (LF-LG)AS with ⬇️ EF, dob stress & AV calcium score are not needed for diagnosis of severe AS. Note: current ACC/AHA staging does not use term ‘critical AS’
✅ Since LV dysfunction here is due to afterload-mismatch LVEF is likely to ⬆️ after AVR. Untreated CAD might impede EF recovery
✅ AS gradient ⬆️ after PVC despite LVEF 20% shows maintained contractile reserve & likely EF recovery after AVR
✅ Post PVC Doppler always helps deeper understanding of physiology! PVCs are not to be missed. Post PVC stroke volume ⬆️ in AS while in HCM it ⬇️
@echo_batman
@argulian
@AnkurKalraMD
@iamritu
@WilliamZoghbi
@PWesslyMD
@alex1708ander
@HeartOTXHeartMD
Prosto Echo retweeted
#echofirst
✅ TTE for recent TIA in a 55 year old (thanks to our talented sonographer Ms. Chris Melson-Alsip)
✅ Details re Diagnosis & other comments?
@OungSavly
@swatigar
@WithAScalpel
@loomba_rohit
@Bravo__MD
@HeartOTXHeartMD
@iamritu
@alex1708ander
@alexsfelixecho
@argulian
Prosto Echo retweeted
Low flow low gradient aortic stenosis can be graded anatomically using aortic valve calcification or hemodynamically using mean gradient to effective orifice area ratio. The most common pattern of discordant grading? Hemodynamically severe and anatomically non-severe
What are potential explanations? Read below
ahajournals.org/doi/10.1161/…
Prosto Echo retweeted
PISA can quantify only central AR. With eccentric AR, PISA fails. Volumetrics is the way to go. #echofirst @NMerke
Prosto Echo retweeted
#echofirst
✅ TEE done pre valve replacement
✅ Comments?
@iamritu
@argulian
@echo_batman
@sudarshanballa
@KemalogluOz
@BryanTanMD
@AnkurKalraMD
Prosto Echo retweeted
35-year-old woman, with no cardiovascular history, asymptomatic.
What is your diagnosis?
Prosto Echo retweeted
Some technical pearls from our first few SESAME cases @MSMorningside @MountSinaiHeart
1 Engagement angle